--- title: Data Centre Construction emoji: ๐Ÿ”Œ colorFrom: blue colorTo: indigo sdk: static pinned: false license: apache-2.0 short_description: Nameplate OCR checked against the equipment schedule --- # Data Centre Construction > **Constructelligence is developing frontier construction-AI models.** This demo is the *lite*, open tier > of the Data Centre Construction kit (see [constructelligence.co](https://constructelligence.co)). **Read an equipment nameplate and know if it is the unit the schedule asked for.** Photograph the nameplate of a UPS, PDU, switchgear, generator, transformer, busway, battery, CRAH, chiller โ€” or a **server rack**. This runs OCR in your browser, pulls out **31 plate fields** across **55 data-centre equipment types**, and **checks each one against the equipment schedule**, flagging a mismatch instead of a silent pass. It builds an asset register and exports it to CSV. Nothing is uploaded: the photo and the schedule stay on your device. ## Try it 1. Drop an equipment schedule as CSV (or click **Use sample schedule**). 2. Drop a nameplate photo (or click **Try a sample nameplate**). 3. Click **Read nameplate** and check the verdict, field by field, against the plate. Sample plates include a matching UPS, a wrong-voltage UPS, a switchboard, a server and a rack PDU. ## How it works - **Photo check** โ€” a quick blur/glare/darkness/resolution read warns before you rely on a bad shot. - **OCR** โ€” `tesseract.js@5` (English LSTM), loaded from a CDN, plus an error model for the way OCR misreads plate lettering (serifed `V`โ†’`Vv`, `K`โ†’`X` in `KVA`, `HZ`โ†’`Hw`, codes split after their punctuation). - **Extraction** โ€” labelled-field parsing with numeric range guards, grouped into Identification, Electrical, Cooling, Server racks/IT and Mechanical. Fields include voltage, phase, Hz, kVA, kW, amps, power factor, MCA, MOCP, SCCR, enclosure, listings, battery type/Ah/cells, refrigerant, charge, cooling tons, BTU/h, CFM, GPM, rack U, power W, PDU outlets, ports, speed and weight. - **Typing** โ€” 55 equipment families, device wording ranked above its family (server racks included). - **Matching** โ€” model and serial codes compared with `O/0`, `I/L/1`, `S/5`, `B/8`, `Z/2` folded, so a misread is not a false mismatch while a genuine voltage variant still fails. ## Links - **Model card and code** โ€” [constructelligence/data-centre-nameplates](https://huggingface.co/constructelligence/data-centre-nameplates) - **Constructelligence** โ€” [huggingface.co/constructelligence](https://huggingface.co/constructelligence) ยท [constructelligence.co](https://constructelligence.co) > A prompt to look, not a finding. Not safety-rated, not a compliance decision, and not a substitute for > inspection by a competent person.